AC Leaking Water — Why It Happens and What To Do First
Water around the indoor unit, or a stain spreading on the ceiling below it — almost always a drain problem, not a refrigerant one.
Act now
Treat this as urgent. The air conditioning repair is usually small; the drywall, insulation and flooring repair that follows an ignored attic leak routinely costs more than the HVAC work.
A Florida air conditioner pulls a startling amount of water out of the air — gallons a day in summer — and all of it is supposed to leave through a condensate drain. When you see water where it should not be, the drain has stopped doing its job. Refrigerant leaks do not produce puddles; that is worth knowing, because the two get confused and they are very different repairs.
The first thing to do is turn the system off at the thermostat. That stops the coil producing more condensate while the water has nowhere to go, which stops the leak getting worse. Then, if you can reach it safely, look at the drain pan under the indoor unit. If it is full, the drain line is blocked. If the pan itself is rusted through or cracked, the pan is the fault.
There is a second reason this matters more than it looks. Most Florida air handlers sit in an attic, directly above a finished ceiling. There is supposed to be a float switch that cuts the system off before the pan overflows — and one of the most common things we find is that a previous visit bypassed it, because a switch that keeps shutting the system down is inconvenient. That bypass is why a blocked drain turns into a ceiling repair.
Before you call anyone
Check these first — they cost nothing
- Turn the system off at the thermostat — this is the one action that stops it getting worse
- Look for standing water in the drain pan under the indoor unit, if it is safely reachable
- Check whether the secondary drain line outside is dripping — it is an alarm, not normal drainage
- Check the air filter; a filter so clogged the coil freezes will drip heavily once it thaws
- Move anything valuable out from under an attic or closet air handler
- Do not pour bleach into the drain line — it damages some pans and components

If the checks above do not resolve it, the causes below need instruments — pressures, temperature split and static pressure — rather than guesswork.
What it usually turns out to be
A blocked condensate drain line
By far the most common. Warm, damp, dark and narrow is ideal for biological growth, and eventually the line closes up entirely. Clearing it is quick; keeping it clear is the actual service.
A bypassed or failed float switch
The safety that should have shut the system down before the pan overflowed. When we find one wired out, that is the reason the leak reached the ceiling.
A rusted or cracked drain pan
Pans do not last forever, particularly secondary pans in attics. Once one is holed, clearing the drain will not stop the leak.
A frozen coil that has thawed
Ice on the coil melts faster than the pan and drain can carry it away, so it overflows. The leak is the symptom; the freeze is the fault, and that is airflow or charge.
A disconnected or badly pitched drain line
A line that has come apart in the attic, or one that was never pitched properly and holds water. Common after other work has been done nearby.
A shared riser blockage, in condos and high-rises
The blockage may not be in your unit at all. Knowing that before spending an hour on your own drain is the difference between a fix and a repeat visit.
AC Leaking Water — common questions
Can I clear the drain myself with a shop vacuum?
Sometimes, from the outdoor end, and it is a reasonable thing to try. What that will not do is tell you why it blocked, check the pan for corrosion, or confirm the float switch actually works — which are the parts that stop it happening again.
My ceiling already has a stain. What now?
Turn the system off, and get the leak stopped before the ceiling is repaired — a repaired ceiling under an unfixed drain is money spent twice. It is also worth photographing the damage before anything is touched, in case it becomes an insurance matter.
Why does it only leak sometimes?
A partially blocked line keeps up in mild weather and cannot keep up on a humid afternoon when the system is producing far more condensate. Intermittent leaks are not a reason to wait; they are the early part of the same failure.
Related symptoms
Frozen AC
Ice on the copper line, the indoor coil or the outdoor unit — always caused by one of two things, and neither of them is 'it's cold'.
Read moreAC Not Cooling
The system is running, air is coming out, and the house still will not get to the thermostat setting.
Read moreAC Making Noise
The sound tells you a great deal about which component is failing — and which noises mean shut it off now.
Read moreWant someone to just look at it?
Open 24 hours, 7 days a week. Someone answers the phone at 3 AM. Not a machine.